Comparison of the Refraction Precision Results between Pentacam AXL and IOL Master 700 Using Universal II Barrett Formula after Cataract Surgery

., Budiman and Melino, Tjokrovonco Ludwig and Dwi, Sugiarti Emmy and Maximilian, Knoch Andrew (2023) Comparison of the Refraction Precision Results between Pentacam AXL and IOL Master 700 Using Universal II Barrett Formula after Cataract Surgery. Open Journal of Ophthalmology, 13 (01). pp. 1-12. ISSN 2165-7408

[thumbnail of ojoph_2023010411091931.pdf] Text
ojoph_2023010411091931.pdf - Published Version

Download (1MB)

Abstract

Background: The availability of premium intraocular lenses (IOL), including toric, multifocal, and EDOF, has become very sophisticated and now demands accurate biometric measurement accuracy. The Pentacam AXL and IOL Master 700 are often used for optical biometry and they are available in the market today. They can also be used to measure the parameters needed in the IOL calculation using the latest generation formulas, such as the Barett Universal II. Therefore, this study aims to compare the accuracy of refraction results between Pentacam AXL compared to IOL Master 700 after cataract surgery with the Barett Universal-II formula. Method: A total of 64 eyes from 64 patients who had a preoperative examination with IOL Master 700 and Pentacam AXL were included in this study. Parameters such as K, ACD, LT, WTW, and AL were then compared between the two tools. Prediction error values were also calculated and compared based on the difference between the Spherical equivalent (SE) of subjective refraction results after 4 weeks of surgery with their refractive prediction targets. Results: There was no statistically significant difference in the parameters measured from the two tools except ACD and WTW. Furthermore, LT was difficult to obtain on the Pentacam AXL due to penetration problems, as well as in patients with significant lens opacities. The percentage of error prediction values that reach ± 0.50 D on Pentacam AXL and IOL Master 700 was 70.3% and 73.5%, respectively. However, the average prediction error that was close to emmetropia with IOL Master 700 was greater compared to the other tool. Conclusion: Pentacam AXL has a fairly good accuracy for refraction prediction compared to IOL Master 700. However, it is still necessary to optimize its constants to obtain optimal results.

Item Type: Article
Subjects: Digital Academic Press > Medical Science
Depositing User: Unnamed user with email support@digiacademicpress.org
Date Deposited: 09 Feb 2023 09:52
Last Modified: 20 Jun 2024 13:23
URI: http://science.researchersasian.com/id/eprint/322