Umehara, Kensuke and Ota, Junko and Ishimaru, Naoki and Ohno, Shunsuke and Okamoto, Kentaro and Suzuki, Takanori and Ishida, Takayuki (2017) Performance Evaluation of Super-Resolution Methods Using Deep-Learning and Sparse-Coding for Improving the Image Quality of Magnified Images in Chest Radiographs. Open Journal of Medical Imaging, 07 (03). pp. 100-111. ISSN 2164-2788

[thumbnail of OJMI_2017091416103266.pdf] Text
OJMI_2017091416103266.pdf - Published Version

Download (1MB)

Abstract

Purpose: To detect small diagnostic signals such as lung nodules in chest radiographs, radiologists magnify a region-of-interest using linear interpolation methods. However, such methods tend to generate over-smoothed images with artifacts that can make interpretation difficult. The purpose of this study was to investigate the effectiveness of super-resolution methods for improving the image quality of magnified chest radiographs. Materials and Methods: A total of 247 chest X-rays were sampled from the JSRT database, then divided into 93 training cases with non-nodules and 154 test cases with lung nodules. We first trained two types of super-resolution methods, sparse-coding super-resolution (ScSR) and super-resolution convolutional neural network (SRCNN). With the trained super-resolution methods, the high-resolution image was then reconstructed using the super-resolution methods from a low-resolution image that was down-sampled from the original test image. We compared the image quality of the super-resolution methods and the linear interpolations (nearest neighbor and bilinear interpolations). For quantitative evaluation, we measured two image quality metrics: peak signal-to-noise ratio (PSNR) and structural similarity (SSIM). For comparative evaluation of the super-resolution methods, we measured the computation time per image. Results: The PSNRs and SSIMs for the ScSR and the SRCNN schemes were significantly higher than those of the linear interpolation methods (p < 0.001 or p < 0.05). The image quality differences between the super-resolution methods were not statistically significant. However, the SRCNN computation time was significantly faster than that of ScSR (p < 0.001). Conclusion: Super-resolution methods provide significantly better image quality than linear interpolation methods for magnified chest radiograph images. Of the two tested schemes, the SRCNN scheme processed the images fastest; thus, SRCNN could be clinically superior for processing radiographs in terms of both image quality and processing speed.

Item Type: Article
Subjects: Digital Academic Press > Medical Science
Depositing User: Unnamed user with email support@digiacademicpress.org
Date Deposited: 27 Mar 2023 06:33
Last Modified: 14 Sep 2024 04:03
URI: http://science.researchersasian.com/id/eprint/720

Actions (login required)

View Item
View Item